CBPDM - MICROTOX ACUTE TOXICITY REAGENT, 686023

  • MSDS: CBPDM
  • Manufacturer: MICROBICS CORP
  • Product Name: MICROTOX ACUTE TOXICITY REAGENT, 686023
  • National Stock Number: 6630-00N071601
Product Identification

Product ID:MICROTOX ACUTE TOXICITY REAGENT, 686023
MSDS Date:02/23/1995
FSC:6630
NIIN:00N071601
MSDS Number: CBPDM

Responsible Party
MICROBICS CORP
2232 RUTHERFORD RD
CALSBAD, CA 92008-8883
US

Emergency Phone: 619-438-8282

Info Phone: 619-438-8282

Cage: 76287

Contractor
MICROBICS CORP
CARLSBAD, CA 92008 US

Telephone: 619-438-8282

Cage: 76287

Ingredients

MICROBIAL GROWTH MEDIUM; (VIBRIO FISCHERI)

Fraction By Weight: 4%

OSHA PEL N/K

ACGIH TLV: N/K


SODIUM CHLORIDE (NACL) (SODIUM CHLORIDE IS COMMON TABLE

CAS: 7647-14-5

RTECS: VZ4725000

Fraction By Weight: 2%

OSHA PEL N/K

ACGIH TLV: N/K


NON HAZARDOUS INGREDIENT; (SKIM MILK SOLIDS)

Fraction By Weight: 94%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:RAT ORAL LD50 DATA IS NOT ESTABLISHED.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VIBRIO FISCHERI-HAS NOT BEEN
REPORTED TO CAUSE DISEASE IN MAMMALS. SODIUM CHLORIDE-MAY CAUSE EYE
IRRITATION. INGESTION OF LARGE QUANTITIES CAN CAUSE VOMITING,
DIARRHEA AND DEHYDRATION. ORAL RAT LD50 DATA IS NOT ESTABLISHED
FOR REAGENT. PRODUCT CONTAINS 2% SODIUM CHLORIDE. PURE SODIUM
CHLORIDE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: DISPLAYS RAT LD50 OF 3000 MG/KG.
CHRONIC: NOT CONSIDERED TO BE HARMFUL AND NO SYMPTOMS OF
OVEREXPOSURE EXIST WHICH CAUSE ANY MEDICAL CONDITION(S).
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) . SKIN: FLUSH W/COPIOUS
AMOUNTS OF WATER. CALL MD . EYES: IN CASE OF CONTACT, FLUSH W ITH
COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. IF LARGE
QUANTITIES INGESTED, CALL A PHYSICIAN.

Fire Fighting

Extinguishing Media:IF IN A FIRE, WATER MAY BE USED AS EXTINGUISHING
MEDIUM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE OR EXPLOSION
HAZARD. DOES NOT REQUIRE SPECIAL CONTROL MEASURED.

Accidental Release

Spill Release Procedures:SPILLED MATERIAL MAY BE ABSORBED WITH PAPER
TOWELS AND DISPOSED OF IN AN APPROVED WASTE DISPOSAL FACILITY.
EXCESS LIQUID MAY BE FLUSHED DOWN A SEWER DRAIN. ENSURE COMPLIANCE
WITH LOCAL, STATE AND FEDE RAL REGULATIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Appearance and Odor:DRY WHITE PELLET. AFTER HYDRATION, SLIGHTLY TURBID,
OFF-WHITE SOLUTION.

Stability

Stability Indicator/Materials to Avoid:NO
THE CHEMICAL PROPERTIES OF THE POWDER MIXTURE ARE CONSIDERED STABLE.
Stability Condition to Avoid:STABLE UNDER ORDINARY ROOM CONDITIONS OF
USE AND STORAGE.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.